☎ +91-22-25789133 / 34  |  +91-7700910447 / +91-7700930447
International Equipments - Plastic Testing Machines Manufacturer Logo
ISO Certified Company

VSP / HDT Apparatus

Polymer Testing Equipment

VSP / HDT Apparatus Manufacturer, Supplier & Exporter

Vicat Softening Point & Heat Deflection Temperature apparatus, as per ASTM D1525, ASTM D648, ISO 306 and ISO 75.

  • Determines Vicat softening & heat deflection temperature
  • As per ASTM D1525, ASTM D648, ISO 306 & ISO 75
  • Temperature range from ambient to 300°C
  • Computerised (2–6 station) & analogue (2 station) models
  • Heating rates of 120°C/hour and 50°C/hour
  • Weight set 5–2000 g; sensor/dial gauge 10 mm, 0.01 mm resolution
Overview

About the VSP / HDT Apparatus

The VSP / HDT Apparatus — Vicat Softening Point and Heat Deflection Temperature apparatus — is used to determine the vicat softening temperature and heat deflection (heat distortion) temperature of polymers, compounds and engineering plastics, as per ASTM D1525, ASTM D648, ISO 306 and ISO 75. These temperatures indicate the point at which a plastic begins to soften or deflect under a defined load, which is critical for selecting materials for parts that operate at elevated temperatures.

A specimen is immersed in a heated bath under a standard load while a sensor (or dial gauge) tracks penetration or deflection as the temperature rises at a controlled rate. International Equipments offers a Computerised model with 2 to 6 stations, which displays VSP and HDT results on a microcontroller and produces Penetration/Deflection vs Temperature graphs and reports through a PC, as well as an Analogue 2-station model with a dial gauge. Both cover ambient to 300°C with 120°C/hour and 50°C/hour heating rates and a weight set from 5 g to 2000 g.

ASTM D1525ASTM D648ISO 306ISO 75Up to 300°C
Specifications

Specification

Computerised VSP / HDT Apparatus

StandardsASTM D1525 & ISO 306 (Vicat softening); ASTM D648 & ISO 75 (heat deflection)
Temperature RangeFrom ambient to 300°C
No. of StationsWith options of 2 stations to 6 stations
Material of ConstructionInner bath: S.S  |  Outer body: M.S
Rate of Heating120°C / hour and 50°C / hour
SensorRange up to 10 mm with resolution of 0.01 mm
WeightsA set of weights ranging from 5 grams to 2000 grams for incremental loads
Direct Display (Microcontroller)VSP and HDT result
Graphic Display & Printout (PC)Penetration / Deflection vs Temperature graph and numeric reports (vicat softening & heat deflection temperature) via a printer connected to the PC
PaintPowder coated
Power230 Volts, 50 Hz, single phase

Analogue VSP / HDT Apparatus

StandardsASTM D1525 & ISO 306 (Vicat softening); ASTM D648 & ISO 75 (heat deflection)
Temperature RangeFrom ambient to 300°C
No. of StationsTwo
Material of ConstructionInner bath: S.S  |  Outer body: M.S
Rate of Heating120°C / hour and 50°C / hour
Dial GaugeRange up to 10 mm with resolution of 0.01 mm
WeightsA set of weights ranging from 5 grams to 2000 grams for incremental loads
PaintPowder coated
Power230 Volts, 50 Hz, single phase
Applications

Where the VSP / HDT Apparatus Is Used

Softening & Deflection

  • Vicat softening point
  • Heat deflection temperature
  • Thermal performance

Polymers & Compounds

  • Engineering plastics
  • Compound & Resin Testing
  • Filled & reinforced grades

High-Temp Parts

  • Automotive components
  • Electrical & appliance parts
  • Material selection

QC & R&D Labs

  • Grade qualification
  • Multi-station throughput
  • Research & development
FAQ

VSP / HDT Apparatus — FAQs

What is a VSP / HDT Apparatus used for?
It determines the Vicat Softening Point and Heat Deflection Temperature of polymers, compounds and engineering plastics per ASTM D1525, ASTM D648, ISO 306 and ISO 75 — the temperatures at which a plastic softens or deflects under a defined load.
Which standards does it follow?
ASTM D1525 and ISO 306 for Vicat softening, ASTM D648 and ISO 75 for heat deflection.
How many stations and what temperature range?
Computerised: 2 to 6 stations; analogue: 2 stations. Both cover ambient to 300°C with heating rates of 120°C/hour and 50°C/hour.
Computerised vs analogue — what's the difference?
The analogue model uses a dial gauge and 2 stations; the computerised model uses a sensor, offers 2–6 stations, displays VSP/HDT on a microcontroller and produces Penetration/Deflection vs Temperature graphs and reports via PC.
Do you export the VSP / HDT Apparatus?
Yes. We export to more than 50 countries and have equipped over 10,000 laboratories in India and abroad.
Related Products

More Polymers Testing Equipments

Interested in the VSP / HDT Apparatus?

Tell us your material, standard and required number of stations — our engineers will help you choose the computerised or analogue model.